① check electrical, instrumentation, safe explosion-proof devices to ensure that sensitive, accurate and reliable.

② check oil system tank without water and debris. Oil level the tank height 2/3; valves flexible pump and filter working properly.

③ free waterway system checks the entire system leakage, pressure was 294 2kPa.

④ inspection system without clogging the intake system and water saving solution, all valves of the exhaust system (exhaust valve, safety valve, check valve) flexible movements.

⑤ start the pump so that the full oil lubrication, check the oil pressure and oil and is normal.

⑥ check axial axle level meter should be at zero, in and out of the valve should be opened.